Reconstitution chart

How much bac water for 5,000 IU HCG?

Concentration and U-100 syringe unit chart for a 5,000 IU vial. Measurement arithmetic for preparing research solutions. For laboratory research use only.

Most labs add 2 mL of bacteriostatic water to a 5,000 IU HCG vial, giving 2,500 IU/mL, so 10 units on a U-100 insulin syringe (0.1 mL) holds 250 IU. Alternatives: 1 mL gives 5,000 IU/mL; 1.5 mL gives 3,333 IU/mL; 2.5 mL gives 2,000 IU/mL. Less water gives a stronger solution and fewer units per draw; more water gives finer resolution per unit.

5,000 IU HCG reconstitution chart

Concentration = 5,000 IU divided by the mL of water added. On a U-100 insulin syringe, 100 units = 1 mL, so 10 units = 0.1 mL. Units for a given amount = amount / concentration x 100.

Bac water addedConcentrationIn 10 units (0.1 mL)Units for 100 IUUnits for 250 IUUnits for 500 IUUnits for 1,000 IU
1 mL5,000 IU/mL500 IU251020
1.5 mL3,333 IU/mL333 IU37.51530
2 mL2,500 IU/mL250 IU4102040
2.5 mL2,000 IU/mL200 IU512.52550
3 mL1,667 IU/mL167 IU6153060

Highlighted row = the common default for this vial. Unit values are on a U-100 insulin syringe (100 units = 1 mL), rounded to 0.1 unit; read to the nearest graduation your syringe has.

How to reconstitute 5,000 IU HCG

  1. Equilibrate. Let the sealed vial and the bacteriostatic water reach room temperature (about 15 to 20 minutes) to limit condensation and help the powder dissolve.
  2. Swab both stoppers. Wipe the rubber stopper of the peptide vial and of the water vial with a fresh alcohol swab and let them air-dry.
  3. Measure the water. Draw 2 mL of bacteriostatic water (or your chosen volume from the chart) with a sterile syringe.
  4. Add it down the vial wall. Insert the needle through the stopper at an angle and release the water slowly down the inside wall of the vial, not directly onto the powder.
  5. Swirl, do not shake. Gently swirl or roll the vial until the powder is fully dissolved and the solution is clear. Allow a few minutes; some peptides dissolve slowly.
  6. Label it. Write the date and the concentration (2,500 IU/mL at the default volume) on the vial.
  7. Refrigerate. Store the reconstituted vial at 2 to 8 °C, protected from light.

More detail: bacteriostatic vs sterile water and reading insulin syringes.

Storage after reconstitution

  • Keep the reconstituted vial at 2 to 8 °C (refrigerator, not the door), protected from light.
  • Lumera's product pages list 28 days at 2 to 8 °C in the original vial; follow the window on the lot's COA. Bacteriostatic water's benzyl alcohol limits microbial growth across repeated stopper punctures; sterile water does not.
  • Do not refreeze the working vial. For longer holding, divide into aliquots once and freeze, avoiding repeated freeze-thaw cycles.
  • Unopened lyophilized vials keep best frozen (-20 °C). See the peptide storage temperature guide.

Troubleshooting

The solution is cloudy

Give it time: let the vial stand in the fridge for 15 to 30 minutes and swirl gently again. If cloudiness, particles or a colour change persist after the powder has dissolved, do not use the solution for quantitative work; discard it.

Foam or bubbles

Usually caused by shaking or by streaming water onto the powder. Let the vial rest upright in the fridge until the foam settles, and next time add the water slowly down the vial wall and swirl instead of shaking.

Left out at room temperature overnight

Degradation speeds up at room temperature, and how much is lost varies by peptide. Return the vial to 2 to 8 °C, note the excursion on the label, and for work where exact concentration matters, prepare a fresh vial.

HCG 5,000 IU

HCG 5,000 IU: $45 CAD per vial. Certificate of Analysis available on request.

Bacteriostatic water: 3 mL $10 CAD or 10 mL $15 CAD.

View HCG 5,000 IU Bacteriostatic water Peptide calculator

Other sizes

HCG reconstitution FAQ

How much bacteriostatic water do I add to 5,000 IU HCG?

Most labs add 2 mL, which gives 2,500 IU/mL. Alternatives: 1 mL gives 5,000 IU/mL; 1.5 mL gives 3,333 IU/mL; 2.5 mL gives 2,000 IU/mL. The volume is a choice; what matters is recording the resulting concentration on the vial label.

How many units is 500 IU of HCG in a 2 mL mix?

At 2,500 IU/mL, 500 IU is in 20 units on a U-100 insulin syringe (0.2 mL). Units = amount / concentration x 100.

What concentration does 5,000 IU HCG make with 2 mL of water?

5,000 IU divided by 2 mL is 2,500 IU/mL, so each 10 units (0.1 mL) holds 250 IU.

How long does reconstituted HCG last in the fridge?

Lumera's product pages list reconstituted solutions as stable for 28 days at 2 to 8 °C in the original vial, protected from light. Use within the window noted on the lot's COA and discard if the solution turns cloudy, changes colour or shows particles.

Should I shake the HCG vial to dissolve it?

No. Swirl or roll the vial gently and let it stand a few minutes. Shaking creates foam and can degrade peptides.

All reconstitution charts by peptide · Peptide calculator for custom volumes.

Research use only. This page is measurement arithmetic for preparing research solutions from a lyophilized vial. It is not a dosing guide. Lumera Labs supplies peptides as laboratory reference standards; they are not approved drugs and are not intended for therapeutic use.